Logo
User Name

Senad Smaka

Društvene mreže:

Mirza Batalovic, Mirza Matoruga, S. Smaka, Fuad Pašalić

Electromagnetic levitation represents a contemporary line of technology with a wide spectrum of applications in several areas of engineering. Regarding the increased demands for this technology in-depth research into its dynamics and the influence of different material characteristics used in these systems is needed. This paper presents simulation results of electrodynamic levitation system regarding different types of materials used for levitating disc. The main intention is to provide a comparison of electrodynamic levitation systems with different materials used for levitating disc in order to improve the system itself. Therefore, the impact of different materials used for the levitating disc of the electrodynamic levitation system would be investigated through some parameters of interest such as an analysis of the electromagnetic force, disk displacement, and the time required to achieve a stable disk position.

Fuad Pašalić, Mirza Batalovic, S. Smaka, S. Berberovic, Mirza Matoruga

This paper presents assessment of selected concept of medium voltage (MV) and low voltage (LV) power supply system of motorway energy consumers/systems on the Pan-European motorway corridor, branch Vc, in Bosnia and Herzegovina (BiH) through methods of reliability analyses. Assessment of selected concept is performed through comparison with different, enhanced and reduced, possible MV network and MV/LV transformer substation configurations. Comparison and analysis of different configurations have been made using of serial, parallel, serial-parallel and delta-star reliability model and Fault tree model. Objective was to confirm that selected concept offers optimized technical solution which provides reliable power supply, failure rate of the supply system as low as possible, together with relative simplicity of design. The results from the selected approach of reliability analyses indicate that this power supply concept entirely based on direct power supply from the primary transformer stations 110/x kV, which ensures two-sided MV power supply of MV/LV transformer substations and their redundant configuration provides reliable power supply of motorway consumers.

Direct current (DC) power systems are gaining interest in the last decade due to increased utilization of DC outputted power sources, DC based energy storage (ES) elements and DC inputted loads. Microgrids are also becoming widely researched as the main foundation of smart grid. It is therefore logical to try to utilize DC microgrid (DCMG) concepts in organization of power systems in wide range of applications. DC microgrids have several important advantages compared to alternating current (AC) microgrids. The control system is essential in order to keep DCMG operating properly, reliable and efficient. Their control structures, with special interest in hierarchical control are explored and compared in this paper in terms of architecture and techniques. This paper presents real world applications using DCMG concept. Future research propositions given in the final chapter can be used as a foundation for researchers exploring the area.

A building-integrated microgrid (BIM) has been a widely utilized concept in low-carbon smart cities. The key advantages of microgrids are using locally available renewable energy sources (RES) and reducing dependency on fossil fuels. Solar photovoltaic (PV) systems and battery storage systems play a crucial role in BIM to achieve desired goals. Due to legal/regulatory and technical restrictions, the distribution system operator (DSO) often imposes zero energy export (ZEE) for these microgrids. Therefore, the sizing of solar-battery systems in BIM, which will be technically feasible and economically optimized, is a challenge for designers, owners and DSO. The objective of this paper is to show the practical approach for design and sizing a microgrid for public buildings using the real data sets of a power consumption and solar energy production. As an example, the BIM for the Faculty of Electrical Engineering, University of Sarajevo is presented.

Nearby lightning strokes are often considered as a prime source of transient overvoltages in the substations. Lightning overvoltages can cause unreliable operation of power system and power supply interruptions. Calculation of expected lightning overvoltages is necessary to design appropriate protection system. This paper presents the analysis of the lightning overvoltage performance of real 400 kV overhead transmission line and gas insulated substation (GIS), considering various factors, such as lightning stroke locations, peak currents, front rise times, etc. EMTP-RV software was used to model transmission line and substation elements and conduct simulations, while transmission line lightning performance was determined using Sigma Slp software. The expected overvoltages and surge arrester currents are calculated and used to design lightning protection system of the considered substation. Obtained results also indicate the importance of proper modelling of power system elements and lightning strokes.

Nermin Colo, S. Huseinbegović, S. Smaka, Branislava Peruničić Dračenović, S. Masic

Energy consumed by trams is studied in many papers, with a wide diversity of approaches regarding how to model and solve this problem. A novel approach to modeling the power consumption of trams is presented in this paper. To identify the unknown parameters influencing the rolling resistance force acting on the tram, it is necessary to measure the power consumption and speed of a single tram (or multiple trams if there are different car types in operation). The developed model of the tram is calibrated with data from the Sarajevo tram system. Simulation results are compared with measurements and a good correlation was obtained. The power consumption model of the tram with identified parameters can be further used to develop a framework for the power consumption estimation of the traction substation.

The method of power transformer neutral point grounding is very important for power distribution network operation because it strongly affect the shapes and values of overvoltages and fault currents. Many methods of grounding are used in medium voltage (MV) power distribution networks. The selection of grounding method largely depends on the characteristics of power network connected to the substation. It is also necessary to consider the advantages and disadvantages of various neutral grounding methods during selection process to find the best solution from a technical and economical point of view. The effects of grounding methods on the characteristics of single-phase short circuit fault are discussed in this paper on the example of 110/20 kV substation ′′Bugojno′′. Modeling and simulation of the considered substation, power transmission and distribution lines are implemented in EMTP-RV software.

Transient events, especially those related to the short circuit faults, are the main causes of power distribution lines outages. This paper is dedicated to the analysis of three-phase short circuit fault and its impact to the real 20 kV power distribution lines. One of the most important parts of Bosnia and Herzegovina's power system was monitored and analyzed. Short circuit currents and voltages were obtained by using the power distribution lines numerical protection system measurements from the moment of fault occurrence to the moment when the faulty line was switched off. Part of the power system of interest was modeled in EMTP-RV (Electromagnetic Transient Program - Restructured Version) software which is standardized software for transient analyses. Several simulations were conducted to perform fault analysis. Measured data and simulation results were compared.

Najla Delić, S. Grebović, S. Smaka, Harun Kartal

Overvoltages are unpredictable and extremely dangerous for the electric power system. The causes of overvoltages are different, but lightning is considered as one of the most serious causes of overvoltages. High voltage substations are one of the main parts of the power system whose faults caused by overvoltages can lead to outage of large part of power system. Therefore, overvoltage protection of a high voltage substation is very important. In order to protect the substation as much as possible from the effects of the overvoltages, it is necessary to implement elements that can help reduce these effects, for example surge arresters. This paper presents the effects of the use of surge arresters in high voltage, gas SF6 insulated substation, modeled in the EMTP-RV (Electromagnetic Transient Program-Restructured Version) software. An accurate representation of lightning surge incoming in the substation is very important because it strongly affects the design of overvoltage protection system. In this paper parameters of lightning strikes are determined using Sigma Slp software.

Short circuit faults are one of the most common disturbances in power systems that occur because of insulation failure due to a sudden overvoltage condition caused by lightning, switching operations, insulation contamination, etc. Medium voltage power distribution networks use different methods for grounding the neutral point. Influences of these grounding methods on the characteristics of single-phase short circuit fault are discussed in this paper on the example of substation “Bugojno”. Modeling and simulation are implemented in EMTP-RV (Electromagnetic Transient Program-Restructured Version) software. Data recorded by protection system during normal operation and three-phase short circuit fault in the substation are analyzed and used for comparison with simulation results to validate developed model of the observed part of power system. This validated model was then used to analyze the effects of neutral point grounding methods on the characteristics of single-phase short circuit fault.

...
...
...

Pretplatite se na novosti o BH Akademskom Imeniku

Ova stranica koristi kolačiće da bi vam pružila najbolje iskustvo

Saznaj više