Production of building materials is mostly energy consuming. In the sphere of insulation materials we mostly see rock wool based materials or foam-plastic materials whose production process is demanding from material aspect and raw materials aspect as well. At present the demand for thermal insulation materials has been growing globally. The thermal insulation materials form integral part of all constructions in civil engineering. The materials mainly fulfill the thermal insulating functions and also the sound-insulating one. The majority of thermal insulation materials are able to fulfill both of the functions simultaneously. The paper describes questions of thermal insulation materials development with good sound properties based on natural fibres that represent a quickly renewable source of raw materials coming from agriculture. The main advantage of the materials are mainly the local availability and simple renewability of the raw materials. In addition an easy recycling of the materials after their service life end in the building construction and last but not least also the connection of human friendly properties of organic materials with advanced product manufacture qualities of modern insulation materials.
Because of the high energy demand required to heat a production hall, the aim of this project is to find out whether it is possible to verify the heating consuming process for heating with the standard simplified calculation method [1], especially for cold regions such as Kosice (Slovakia). The energy requirement for heating a case study industrial building was evaluated using measurements and calculations.During the winter period, energy consumption was measured in the selected industrial building according to a validation standard [2]. The building is comprised of two halls. The measurements were analyzed according to the criteria used for validating residential and public buildings, with several regression dependencies taken into account in the resulting evaluation of heating energy consumption. The mathematical dependencies of measured values in real conditions are shown in this paper. In addition, the building’s heating energy demand was calculated according to the Austrian standard [3], ONORM EN ISO 13790, the simplified calculation method for non-residential buildings. It was investigated whether the measured values could be replicated using this calculation. It was found that the precise definition of the internal heat gains is very important.
Nema pronađenih rezultata, molimo da izmjenite uslove pretrage i pokušate ponovo!
Ova stranica koristi kolačiće da bi vam pružila najbolje iskustvo
Saznaj više