Logo

Publikacije (17)

Nazad

Abstract This paper presents a detailed model of low-frequency oscillations and their damping within the Electric Power System (EPS) of Bosnia and Herzegovina (B&H). The system is modeled using MATLAB software, analysing the steady state and dynamic responses. This research highlights the challenges and impacts of integrating renewable energy sources, such as wind farms, on grid stability and oscillation damping. The paper utilizes eigenvalue analysis to investigate the dynamic characteristics of the system, emphasizing the need for efficient damping strategies to maintain system stability. The methodology includes a comprehensive review of existing literature, the creation of a detailed EPS model of B&H, and the application of eigenvalue and oscillation amplitude analysis to determine damping ratios. The dynamic responses of hydro power plants, HPP Mostar and HPP Jablanica, to transient disturbances are analysed to validate the model and refine damping strategies. The results indicate that the B&H EPS is well-damped, with all eigenvalues possessing negative real parts, and demonstrate the system’s resilience to small disturbances. The results are compared with the technical report on the integration of the wind power plant WPP Podveležje. This comparative analysis shows consistent patterns between the modeled calculations and empirical data, confirming the robustness of the EPS model. This alignment underscores the effectiveness of current damping mechanisms and provides a foundational strategy for enhancing system stability with increasing renewable energy penetration. The findings highlight the importance of developing advanced control strategies to sustain system stability as the integration of variable renewable energy sources continues to grow.

Abstract The methodology for the evaluation of long-term exposure to the overhead line magnetic field is presented, in this paper. The developed methodology is based on the ambient temperature measurements and phase conductors’ height measurements to find a linear regression model to determine phase conductors’ height changes for different ambient temperatures. Based on the overhead transmission line geometry, and datasets about historical overhead line phase current intensity values and ambient temperatures long-term magnetic field exposure can be determined. For magnetic flux density determination, a method based on artificial neural networks is used. The methodology is applied to the case study of overhead line that connect substations Sarajevo 10 and Sarajevo 20. A period of one year is analyzed and magnetic flux density values are determined. The obtained results indicate that during the analyzed period for significant amounts of time magnetic flux density values surpass the recommended values for long-term exposure.

Abstract This paper presents an artificial neural network (ANN) based method for overhead lines magnetic flux density estimation. The considered method enables magnetic flux density estimation for arbitrary configurations and load conditions for single-circuit, multi-circuit, and also overhead lines that share a common corridor. The presented method is based on the ANN model that has been developed using the training dataset that is produced by a specifically designed algorithm. This paper aims to demonstrate a systematic and comprehensive ANN-based method for simple and effective overhead lines magnetic flux density estimation. The presented method is extensively validated by utilizing experimental field measurements as well as the most commonly used calculation method (Biot - Savart law based method). In order to facilitate extensive validation of the considered method, numerous magnetic flux density measurements are conducted in the vicinity of different overhead line configurations. The validation results demonstrate that the used method provides satisfactory results. Thus, it could be reliably used for new overhead lines’ design optimization, as well as for legally prescribed magnetic flux density level evaluation for existing overhead lines.

Maja Muftić Dedović, A. Mujezinović, Nedis Dautbašić, Ajdin Alihodžić, Adin Memic, S. Avdakovic

The decrease in overall inertia in power systems due to the shift from synchronous generator production to renewable energy sources (RESs) presents a significant challenge. This transition affects the system’s stable frequency response, making it highly sensitive to imbalances between production and consumption, particularly during large disturbances. To address this issue, this paper introduces a novel approach using Multivariate Empirical Mode Decomposition (MEMD) for the accurate estimation of power system inertia. This approach involves applying MEMD, a complex signal processing technique, to power system frequency signals. The study utilizes PMU (Phasor Measurement Unit) data and simulated disturbances in the IEEE 39 bus test system to conduct this analysis. MEMD offers substantial advantages in analyzing multivariate data and frequency signals during disturbances, providing accurate estimations of system inertia. This approach enhances the understanding of power system dynamics in the context of renewable energy integration. However, the complexity of this methodology and the requirement for precise data collection are challenges that need to be addressed. The results from this approach show high accuracy in estimating the rate of change of frequency (RoCoF) and system inertia, with minimal deviation from actual values. The findings highlight the significant impact of renewable energy integration on system inertia and emphasize the necessity of accurate inertia estimation in modern power systems.

In this paper, a comparative analysis of different methods for magnetic induction estimation in the vicinity of overhead power lines is presented. The methods for determining magnetic induction, considered in the paper, include the recently proposed artificial neural network based method and the Biot-Savart law based method. In addition, the paper considers a method that employs the genetic algorithm to fit a considered mathematical model to the field measurements. The performance of various methods is evaluated on an actual 400 kV overhead power line. The method based on the artificial neural networks is able to accurately evaluate magnetic induction values along the lateral profile without relying on field measurements using only the description of power line conductor configuration and the current intensity value.

Rusmir Skopljak, Ajdin Alihodžić, Maja Muftić Dedović, Nedis Dautbašić, A. Mujezinović

Due to the significant growth in the number of devices, the range of services it provides, and strict air conditioning requirements, the telecommunications infrastructure is becoming an increasingly important electricity consumer. The efficiency of the power supply system and the power quality are significant challenges in the design and maintenance of telecommunications infrastructure elements. In such systems, power electronic converters play an indispensable role. This paper discusses the results of power quality measurements for supply systems of telecommunications devices. The power supply systems of telecommunications devices with different power converters were analyzed. Also, the power supply of a mobile telephony base station at a remote location was considered, with special reference to the reaction of battery storage in the event of a power outage. Obtained results demonstrate that it is necessary to treat such consumers with special care and take measures to limit their emission of current harmonics.

Nedis Dautbašić, Faris Likić, A. Mujezinović, I. Turkovic, Maja Muftić Dedović, Ajdin Alihodžić

The paper presents an algorithm for determining the optimal connection location and power of a photovoltaic plant in a distribution network. The proposed algorithm is based on the use of the fuzzy logic and power flow calculation method. The fuzzy logic is used for the selection of candidate buses for the photovoltaic plant connection, while load flow analysis is used for the verification of voltage conditions and power losses in the distribution network. For each of the candidate buses photovoltaic plant of a certain power range was considered. The practical application of the considered algorithm was demonstrated on a part of Sarajevo's 10 kV distribution network.

Maja Muftić Dedović, S. Avdakovic, Ajdin Alihodžić, Nedis Dautbašić, Adin Memic, A. Mujezinović

This paper presents the use of the Hilbert-Huang Transform (HHT) to identify low-frequency electromechanical oscillatory modes, their characteristics, and damping. As these oscillations can have varying features, locations, and impacts on power systems, identifying and monitoring them is crucial for the monitoring, protection, and control of modern power systems. The Hilbert-Huang transform (HHT) is a technique used to analyze nonlinear and non-stationary time series data. It involves breaking down the data into components using Empirical Mode Decomposition (EMD), which generates components with varying amplitudes and frequencies. The EMD process includes an inner loop called sifting, which produces an Intrinsic Mode Function (IMF) until the signal reaches a mean value of zero or a maximum number of iterations. The obtained IMF is a characteristic function of a fundamental oscillation that is symmetrical around the abscissa. The dominant oscillatory mode's frequency can be determined by applying the Hilbert transformation to the first IMF, and the damping ratio and damping can be calculated by fitting a least square line to the logarithmic instantaneous amplitude of the first IMF. To demonstrate the efficacy of the methodology, three case studies are examined. The first case involves generating a synthetic signal to simulate a load angle change with a defined frequency and damping. In the second case, a small disturbance in mechanical power change in the Single Machine System is simulated. The third case simulates a three-phase short circuit on the transmission line using the IEEE 39 bus test system. The results are compared to modal analysis conducted in DigSilent PowerFactory software. The application of HHT yielded satisfactory and promising results in identifying the dominant mode's oscillation frequency and damping.

This paper considers the application of artificial neural network (ANN) models for electric field intensity and magnetic flux density estimation in the proximity of overhead transmission lines. Specifically, two distinct ANN models are used to facilitate independent estimation of electric field intensity and magnetic flux density in the proximity of overhead transmission lines. The considered ANN approach is systematically evaluated under different scenarios. An example of an overhead transmission line with horizontal phase conductor configuration is used to enable a direct comparison of the electric field intensity and magnetic flux density estimates generated by the two ANN models to measurement results obtained over the lateral profile. Further investigation of ANN models involves an extensive study whereby 13 different overhead transmission lines of horizontal configurations are used as the basis for comparing measurement results to estimates provided by the ANN models. In this study, the performance analysis of the ANN models was evaluated using coefficient of determination and root mean square error. The obtained results demonstrate that the considered ANN approach can be used to estimate the electric field intensity and magnetic flux density in the proximity of overhead transmission lines.

Maja Muftić Dedović, Nedis Dautbašić, Ajdin Alihodžić, Adin Memic

Abstract Underfrequency load shedding is a common technique for maintaining the stability of the power system by removing the overload in a certain part of the system after a disturbance. The purpose of underfrequency load shedding is to balance output and load when a particular event causes a significant frequency drop in the power system. In conventional underfrequency load shedding schemes, the frequency thresholds of frequency relays are constant, this way it is difficult and sometimes impossible to control the frequency in various disturbances in the system. In this paper, an adaptive underfrequency load shedding (AUFLS) algorithm that is independent of communication between relays is presented. The relays are tuned to reduce loads taking into account local parameters such as voltage and frequency to prevent the occurrence of a cascade failure that can ultimately lead to the breakdown of the entire power system. In this paper, the rate of change of frequency (ROCOF) is obtained by applying the Hilbert-Huang transformation. Numerical simulations conducted on the New England 39 bus test system in the DIgSILENT PowerFactory and MATLAB software packages confirm the effectiveness of the proposed approach.

In this paper approach for the experimental determination of the grounding system impulse impedance under the presence of the high-frequency electromagnetic interference is presented. The considered approach is based on the application of the discrete wavelet transform on the measured signals. Validation of the considered approach has been conducted in several experiments using a vertical grounding electrode. The experimental investigation has been performed using different impulse current peak values and different front rise times. On all measured current and voltage waveforms, high-frequency interferences were registered.

This paper considers calculation methods for the electric field intensity and magnetic flux density in the vicinity of the overhead transmission lines, as well as the calculation of alternating current (AC) corona onset electric field intensity. Calculations within this paper are made using the 2D algorithms of Charge Simulation Method (CSM) and Biot-Savart (BS) law based method. In order to obtain more accurate results, calculations are made by representing each overhead transmission line conductor with a large number of electric and magnetic field sources. By applying this approach, bundle conductors can be represented in a more realistic way and also singularity problems can be avoided when calculating electric field intensity. The presented methods are applied to a real overhead transmission line configuration, and obtained results are compared with field measurement results over the lateral profile. For considered overhead transmission line, AC corona onset electric field intensity is calculated and compared with calculated electric field intensity on the conductor’s surface. A comparison of calculated and measured results shows that considered calculation methods give satisfactory results.

This paper considers the method for the calculation of magnetic flux density in the vicinity of overhead distribution lines which takes into account the higher current harmonics. This method is based on the Biot–Savart law and the complex image method. The considered method calculates the values of the magnetic flux density for each harmonic component of the current separately at all points of interest (usually lateral profile). In this way, it is possible to determine the contributions of individual harmonic components of the current intensity to the total value of magnetic flux density. Based on the contributions of individual harmonic components, the total (resultant) value of the magnetic flux density at points of interest is determined. Validation of the computational method is carried out by comparison of the results obtained by the considered calculation method with measurement results. Furthermore, the application of the calculation method was demonstrated by calculating magnetic flux density harmonics in the vicinity of two overhead distribution lines of typical phase conductor arrangements.

In this paper, a novel method for the magnetic flux density estimation in the vicinity of multi-circuit overhead transmission lines is proposed. The proposed method is based on a fully connected feed-forward artificial neural network model that is trained to estimate the magnetic flux density vector components for a range of single-circuit overhead transmission lines. The proposed algorithm is able to simplify estimation process in instances when there are two or more geometrically identical circuits present in the multi-circuit overhead transmission line. In such instances, artificial neural network model is employed to estimate the magnetic flux density distribution over a considered lateral profile for only one of such circuits. The magnetic flux density estimates of the other geometrically identical circuits are derived from these results. The proposed methodology defines the resultant magnetic flux density for the multi-circuit overhead transmission line in terms of the contributions made by individual circuits. The application of the proposed magnetic flux density estimation method is demonstrated on several multi-circuit configurations of overhead transmission lines. The performance of the proposed method is compared with the Biot-Savart law based method calculation results as well as with field measurement results.

Nema pronađenih rezultata, molimo da izmjenite uslove pretrage i pokušate ponovo!

Pretplatite se na novosti o BH Akademskom Imeniku

Ova stranica koristi kolačiće da bi vam pružila najbolje iskustvo

Saznaj više