on Intelligent Manufacturing and Automation , 2013 Optimization of Thermal Insulation and Regression Analysis of Fuel Consumption

In this paper analyses of the current state of the thermal insulation of walls without styrofoam and existing windows of Alipasino polje buildings in Sarajevo, Bosnia and Herzegovina, which is powered boiler K-5 through its substations, and current fuel consumption is performed. Research results lead to the conclusion that it is worth to consider insulation of buildings, i.e., simulation of adding styrofoam and new windows on the existing structure in order to reduce heat losses and thus reduce fuel consumption and gas emissions. Savings obtained by this simulation are over 30%. Surface area of buildings subject to the installation of the insulation is obtained on the basis of projects from the district heating system Toplane Sarajevo. Styrofoam thickness is determined by optimizing reduction of the payback period. Prediction of fuel consumption was evaluated for the existing and projected future depending on outside temperature. © 2014 The Authors. Published by Elsevier Ltd. Selection and peer-review under responsibility of DAAAM International Vienna.