Simple Summary A total laryngectomy and/or pharyngectomy is an important therapy modality for advanced primary and recurrent laryngeal and hypopharyngeal squamous cell carcinoma. The surgical margins are an important prognostic factor. Resection margins for head and neck cancer surgery are clear >5 mm, close 1–5 mm and positive <1 mm. However, the anatomy of the larynx and hypopharynx is complex and resections are constrained by the anatomical relationship with the surrounding structures. The aim of this study is to investigate if a margin >5 mm is feasible. Clear resection margins are not always feasible in some resection surfaces in laryngeal and hypopharyngeal surgery, due to the anatomy of the larynx and tumor location. However, striving for a maximum feasible margin is still the main goal. We propose a new guideline for the maximum feasible but adequate resection margins in larynx and hypopharynx tumor surgery. Abstract Background: Resection margins are an important prognostic factor for patients with head and neck cancer. In general, for head and neck surgery, a margin >5 mm is advised by the Royal College of Pathologists. However, this cannot always be achieved during laryngeal and hypopharyngeal surgery. The aim of this study is to identify the resection surfaces and measure the maximum feasible margins per subsite. The clinical relevance of these maximum feasible resection margins were analyzed in this descriptive anatomical study. Methods: head and neck surgeons and a pathologist from the Erasmus MC performed a total laryngectomy and laryngopharyngectomy on a head and neck specimen specifically available for research. Results: For a total laryngectomy, resection margins >5 mm were not feasible for the ventral and dorsal resection surface. For a total laryngopharyngectomy, resection margins >5 mm were not feasible for the ventral, dorsal and lateral resection surface. Conclusion: Clear resection margins, defined as a margin >5 mm, are not always feasible in laryngeal and hypopharyngeal surgery, due to the anatomy of the larynx and tumor location. However, striving for a maximum feasible margin is still the main goal. We propose a new guideline for maximum feasible but adequate resection margins in larynx and hypopharynx tumor surgery.
Simple Summary Achieving margins of >5 mm is challenging in the larynx and hypopharynx because resections are constrained by their complex anatomy. The aim of this study was to retrospectively assess the clinical relevance of resection margins defined by the RCP in total laryngectomies (TLs) and total laryngopharyngectomies (TLPs). Similar survival rates for close and clear margins for primary and recurrent LSCC were found. This may suggest that a margin > 5 mm is not clinically relevant in terms of survival, therefore a margin of 1–5 mm should be accepted in certain subsites. Margins < 1 mm are related to significantly worse outcomes and should be avoided. Abstract Background: Laryngeal and hypopharyngeal cancer is complex and resection margins are therefore constrained. The aim of this study was to investigate the clinical relevance of resection margins in laryngeal and hypopharyngeal surgery. Methods: A retrospective cohort study was performed for patients treated with a total laryngectomy (TL) or laryngopharyngectomy (TLP) for laryngeal or hypopharyngeal squamous cell carcinoma (LSCC and HSCC, respectively). Within the groups primary LSCC, recurrent LSCC, primary HSCC, and recurrent HSCC the relationship between the status of the resection margin according to the Royal Collage of Pathology and the recurrence and survival rates were investigated. Results: Positive resection margins were found in 54% for primary LSCC, 29% for recurrent LSCC, 62% for primary HSCC, and 44% for recurrent HSCC. For primary and recurrent LSCC, there was a linear association between total recurrence and narrowing margins (p = 0.007 resp. p = 0.008). Multivariate survival analysis for primary and recurrent LSCC showed a significantly worse disease free and disease-specific survival in case of positive margins compared to clear margins. Conclusion: Similar survival rates were recorded for close and clear margins for primary and recurrent LSCC. This may suggest that a margin > 5 mm is not clinically relevant in terms of survival. Therefore, a margin of 1–5 mm should be accepted in certain subsites. Margins < 1 mm are related to significantly worse outcomes and should be avoided.
BACKGROUND Autofluorescence (AF) - Raman spectroscopy is a technology that can detect residual basal cell carcinoma (BCC) on the resection margin of fresh surgically excised tissue specimens. The technology does not require tissue fixation, staining, labelling, or sectioning, and provides quantitative diagnosis maps of the surgical margins in 30 minutes. OBJECTIVES To determine the accuracy of the AF-Raman instrument to detect incomplete excisions of BCC during Mohs micrographic surgery, using histology as reference standard. METHODS Skin layers from 130 patients undergoing Mohs surgery at the Nottingham University Hospitals NHS Trust (September 2022 to July 2023) were investigated with the AF-Raman instrument. The layers were measured fresh, immediately after excision. The AF-Raman results and the intra-operative assessment by Mohs surgeons were compared to a post-operative consensus-derived reference produced by three dermatopathologists. The sensitivity, specificity, positive predictive value, and negative predictive value were calculated. RESULTS The AF-Raman analysis was successfully completed for 125 out of the 130 layers. The AF-Raman analysis covered 91% of the specimen surface area on average, with the lowest being 87% for eyelid and the highest being 94% for forehead specimens. The AF-Raman instrument identified positive margins in 24 out of 36 BCC-positive cases, resulting in a 67% sensitivity (95% confidence intervals (CI): 49%-82%) and negative margins in 65 out of 89 BCC-negative cases, resulting in a 73% specificity (95% CI 63%-82%). Only one out of the 12 false negative cases was caused by misclassification by the AF-Raman algorithm. The other 11 false negatives cases were produced because no valid Raman signal was recorded at the location of the residual BCC due to either occlusion by blood or poor contact between tissue and cassette window. The intra-operative diagnosis by Mohs surgeons identified positive margins in 31 out of 36 BCC-positive cases, 86% sensitivity (95% CI: 70%-95%), and negative margins in 79 out of 89 BCC-negative cases, 89% specificity (95% CI: 81%-95%). CONCLUSIONS This study shows that the AF-Raman instrument has potential for intra-operative microscopic assessment of surgical margins in surgery of BCC. Further improvements are required for tissue processing to ensure complete coverage of the surgical specimens. ClinicalTrials.gov ID NCT03482622.
ABSTRACT Identification of sentinel node (SN) metastases can set the adjuvant systemic therapy indication for stage III melanoma patients. For stage IIIA patients, a 1.0 mm threshold for the largest SN tumour diameter is used. Therefore, uniform reproducible measurement of its size is crucial. At present, the number of deposits or their microanatomical sites are not part of the inclusion criteria for adjuvant treatment. The goal of the current study was to show examples of the difficulty of measuring SN melanoma tumour diameter and teach how it should be measured. Histopathological slides of SN-positive melanoma patients were retrieved using the Dutch Pathology Registry (PALGA). Fourteen samples with the largest SN metastasis around 1.0 mm were uploaded via tele-pathology and digitally measured by 12 pathologists to reflect current practice of measurements in challenging cases. Recommendations as educational examples were provided. Microanatomical location of melanoma metastases was 1 subcapsular, 2 parenchymal and 11 combined. The smallest and largest difference in measurements were 0.24 mm and 4.81 mm, respectively. 11/14 cases (78.6%) showed no agreement regarding the 1.0 mm cut-off. The median discrepancy for cases ≤5 deposits was 0.5 mm (range 0.24–0.60, n=3) and 2.51 mm (range 0.71–4.81, n=11) for cases with ≥6 deposits. Disconcordance in measuring SN tumour burden is correlated with the number of deposits. Awareness of this discordance in challenging cases, for example, cases with multiple small deposits, is important for clinical management. Illustrating cases to reduce differences in size measurement are provided.
Extract COPD is nowadays considered to be a heterogeneous lung condition characterised by chronic respiratory symptoms caused by airway and/or alveolar abnormalities causing persistent airflow obstruction. This airflow obstruction is defined by a post-bronchodilator forced expiratory volume in 1 s (FEV1) to forced vital capacity (FVC) ratio lower than 0.7. However, the recent 2023 Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines also pointed out that some patients can present with symptoms and/or structural changes such as emphysema and/or physiological abnormalities without airway obstruction, defined as pre-COPD, bearing a higher risk for progression to COPD [1]. Shareable abstract There is a severity dependent increase in the size but not the absolute number of interalveolar pores of Kohn in COPD. In addition, the pore size shows important correlations with pulmonary function testing. https://bit.ly/3HL1GJ8
RATIONALE Small airway disease is an important pathophysiological feature of COPD. Recently, pre-COPD has been put forward as potential precursor stage of COPD, defined by abnormal spirometry or significant emphysema on CT in the absence of airflow obstruction. METHODS We collected whole lungs/lung lobes from patients with emphysematous pre-COPD (n=10), COPD GOLD I (n=6), GOLD II (n=6), GOLD III/IV (n=7) and controls (n=10) which were analyzed using CT and microCT. The degree of emphysema and the number and morphology of small airways was compared between the different groups and further correlations were investigated with physiologic measures. Airway and parenchymal pathology was also validated with histopathology. MEASUREMENTS AND MAIN RESULTS The number of transitional bronchioles (TrB)/mL and terminal bronchioles (TB)/mL was significantly lower in pre-COPD, GOLD I, GOLD II and GOLD III/IV compared to controls. In addition, the number of alveolar attachments of the TrB and TB was also lower in pre-COPD and all COPD groups compared to controls. We did not find any differences between the pre-COPD and COPD group in either CT or microCT measures. The % of emphysema on CT showed the strongest correlation with the number of small airways, also in patients without airflow obstruction. Histopathology showed an increase in the mean chord length and a decrease in the alveolar surface density in pre-COPD and all GOLD stages compared to control. CONCLUSION Lungs of patients with emphysematous pre-COPD already show lower small airway number and airway remodeling and in the absence of physiologic airway obstruction.
Single nucleotide point mutations in the KRAS oncogene occur frequently in human cancers, rendering them intriguing targets for diagnosis, early detection and personalized treatment. Current detection methods are based on polymerase chain reaction, sometimes combined with next-generation sequencing, which can be expensive, complex and have limited availability. Here, we propose a novel singlet oxygen (1O2)-based photoelectrochemical detection methodology for single-point mutations, using KRAS mutations as a case study. This detection method combines the use of a sandwich assay, magnetic beads and robust chemical photosensitizers, that need only air and light to produce 1O2, to ensure high specificity and sensitivity. We demonstrate that hybridization of the sandwich hybrid at high temperatures enables discrimination between mutated and wild-type sequences with a detection rate of up to 93.9%. Additionally, the presence of background DNA sequences derived from human cell-line DNA, not containing the mutation of interest, did not result in a signal, highlighting the specificity of the methodology. A limit of detection as low as 112 pM (1.25 ng/mL) was achieved without employing any amplification techniques. The developed 1O2-based photoelectrochemical methodology exhibits unique features, including rapidity, ease of use, and affordability, highlighting its immense potential in the field of nucleic acid-based diagnostics.
As for many solid cancers, laryngeal cancer is treated surgically, and adequate resection margins are critical for survival. Raman spectroscopy has the capacity to accurately differentiate between cancer and non-cancerous tissue based on their molecular composition, which has been proven in previous work. The aim of this study is to investigate whether Raman spectroscopy can be used to discriminate laryngeal cancer from surrounding non-cancerous tissue. Patients surgically treated for laryngeal cancer were included. Raman mapping experiments were performed ex vivo on resection specimens and correlated to histopathology. Water concentration analysis and CH-stretching region analysis were performed in the high wavenumber range of 2500–4000 cm^−1. Thirty-four mapping experiments on 22 resection specimens were used for analysis. Both laryngeal cancer and all non-cancerous tissue structures showed high water concentrations of around 75%. Discriminative information was only found to be present in the CH-stretching region of the Raman spectra of the larynx (discriminative power of 0.87). High wavenumber region Raman spectroscopy can discriminate laryngeal cancer from non-cancerous tissue structures. Contrary to the findings for oral cavity cancer, water concentration is not a discriminating factor for laryngeal cancer.
Buccal squamous cell carcinoma (SCC) appears to behave more aggressively than other oral subsites, in particular with regards to regional disease at presentation and regional recurrence. Adequate management of the neck is of the utmost importance but is still the subject of debate. An international multicentre retrospective review of 101 patients treated for T1-T2 buccal SCC was performed. Twenty-four were staged clinical node positive (cN+) and underwent therapeutic neck dissection, while 77 were node negative (cN0), with 32 undergoing elective neck dissection (END), with an occult nodal metastasis rate of 28.1%. Depth of invasion (DOI) < 4 mm was associated with a significantly lower rate of cervical nodal metastasis (87.5% versus 12.5%; P = 0.033). END demonstrated a non-significantly lower regional recurrence rate compared to observation (6.3% versus 8.9%, P = 0.670). Regional recurrence was more common in pN+ (24%) and undissected cases (8.9%) than in pN0 patients (0%) (P = 0.011) and was associated with DOI > 5 mm (P = 0.002). Regional recurrence resulted in a reduction in survival (24 versus 93 months, P < 0.001). In the pT2cN0 group, END improved survival (123 versus 26 months, P = 0.009). It is suggested that END be performed in cT2N0 buccal SCC, particularly for tumours with DOI > 4 mm.
Patients with oral cavity cancer are almost always treated with surgery. The goal is to remove the tumor with a margin of more than 5 mm of surrounding healthy tissue. Unfortunately, this is only achieved in about 15% to 26% of cases. Intraoperative assessment of tumor resection margins (IOARM) can dramatically improve surgical results. However, current methods are laborious, subjective, and logistically demanding. This hinders broad adoption of IOARM, to the detriment of patients. Here we present the development and validation of a high-wavenumber Raman spectroscopic technology, for quick and objective intraoperative measurement of resection margins on fresh specimens. It employs a thin fiber-optic needle probe, which is inserted into the tissue, to measure the distance between a resection surface and the tumor. A tissue classification model was developed to discriminate oral cavity squamous cell carcinoma (OCSCC) from healthy oral tissue, with a sensitivity of 0.85 and a specificity of 0.92. The tissue classification model was then used to develop a margin length prediction model, showing a mean difference between margin length predicted by Raman spectroscopy and histopathology of -0.17 mm.
Cyclin-dependent kinase 2-associated protein 1 (CDK2AP1; also known as deleted in oral cancer or DOC1) is a tumor suppressor gene known to play functional roles in both cell cycle regulation and in the epigenetic control of embryonic stem cell differentiation, the latter as a core subunit of the nucleosome remodeling and histone deacetylation (NuRD) complex. In the vast majority of oral squamous cell carcinomas (OSCC), expression of the CDK2AP1 protein is reduced or lost. Notwithstanding the latter (and the DOC1 acronym), mutations or deletions in its coding sequence are extremely rare. Accordingly, CDK2AP1 protein-deficient oral cancer cell lines express as much CDK2AP1 mRNA as proficient cell lines. Here, by combining in silico and in vitro approaches, and by taking advantage of patient-derived data and tumor material in the analysis of loss of CDK2AP1 expression, we identified a set of microRNAs, namely miR-21-5p, miR-23b-3p, miR-26b-5p, miR-93-5p, and miR-155-5p, which inhibit its translation in both cell lines and patient-derived OSCCs. Of note, no synergistic effects were observed of the different miRs on the CDK2AP1–3-UTR common target. We also developed a novel approach to the combined ISH/IF tissue microarray analysis to study the expression patterns of miRs and their target genes in the context of tumor architecture. Last, we show that CDK2AP1 loss, as the result of miRNA expression, correlates with overall survival, thus highlighting the clinical relevance of these processes for carcinomas of the oral cavity.
Near-infrared (NIR) fluorescence imaging using exogenous fluorescent agents provides whole-field images in real-time to assist the surgeon in the excision of a tumor. Although the method has high sensitivity, the specificity can sometimes be lower than expected. Raman spectroscopy can detect tumors with high specificity. Therefore, a combination of both techniques can be advantageous. A complication that must be addressed is that the NIR spectral region is favored by both techniques for (in vivo) tissue analysis. When fluorescence and Raman emissions spectrally overlap, it becomes challenging or impossible to detect the Raman signal. In this paper, by avoiding this overlap, we describe a Raman spectroscopy setup capable of recording high-quality Raman spectra from tissue containing NIR exogenous fluorescent agents. We identify an optimal wavelength interval (900-915 nm) for Raman excitation, which avoids both excitation of fluorescent dyes and Raman signal self-absorption by the tissue. In this way, Raman spectroscopy can be combined with the currently most-used NIR fluorescent dyes. This combined novel setup could pave the way for clinical trials benefiting from both fluorescence imaging and Raman spectroscopy to avoid positive margins in cancer surgery.
Nema pronađenih rezultata, molimo da izmjenite uslove pretrage i pokušate ponovo!
Ova stranica koristi kolačiće da bi vam pružila najbolje iskustvo
Saznaj više