Machine Learning Classification of Body Part, Imaging Axis, and Intravenous Contrast Enhancement on CT Imaging
Purpose: The development and evaluation of machine learning models that automatically identify the body part(s) imaged, axis of imaging, and the presence of intravenous contrast material of a CT series of images. Methods: This retrospective study included 6955 series from 1198 studies (501 female, 697 males, mean age 56.5 years) obtained between January 2010 and September 2021. Each series was annotated by a trained board-certified radiologist with labels consisting of 16 body parts, 3 imaging axes, and whether an intravenous contrast agent was used. The studies were randomly assigned to the training, validation and testing sets with a proportion of 70%, 20% and 10%, respectively, to develop a 3D deep neural network for each classification task. External validation was conducted with a total of 35,272 series from 7 publicly available datasets. The classification accuracy for each series was independently assessed for each task to evaluate model performance. Results: The accuracies for identifying the body parts, imaging axes, and the presence of intravenous contrast were 96.0% (95% CI: 94.6%, 97.2%), 99.2% (95% CI: 98.5%, 99.7%), and 97.5% (95% CI: 96.4%, 98.5%) respectively. The generalizability of the models was demonstrated through external validation with accuracies of 89.7 - 97.8%, 98.6 - 100%, and 87.8 - 98.6% for the same tasks. Conclusions: The developed models demonstrated high performance on both internal and external testing in identifying key aspects of a CT series. Graphical Abstract